CS-E24MKES, CU-E24MKE, CS-E28MKES, CU-E28MKE - Panasonic Air Conditioner Service Manual (repair manual). Page 105

Read Panasonic CS-E24MKES / CU-E24MKE / CS-E28MKES / CU-E28MKE Service Manual online

105
17.2. Sensible Capacity Chart
CS-E24MKES  CU-E24MKE
CS-E28MKES  CU-E28MKE
Outdoor Temp. (
“C)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
“C
6.75
5.11
1.94
6.30
4.90
2.09
5.86
4.71
2.23
5.33
4.48
2.41
19.0
“C
6.80
2.12
19.5
“C
7.41
5.35
1.98
6.92
5.14
2.13
6.44
4.95
2.28
5.85
4.71
2.45
22.0
“C
8.07
5.55
2.01
7.54
5.34
2.17
7.02
5.15
2.32
6.38
4.91
2.50
Outdoor Temp. (
“C)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
“C
7.59
5.75
2.33
7.09
5.52
2.50
6.59
5.30
2.68
6.00
5.04
2.89
19.0
“C
7.65
2.54
19.5
“C
8.33
6.02
2.37
7.79
5.79
2.55
7.24
5.57
2.73
6.59
5.30
2.94
22.0
“C
9.08
6.25
2.41
8.48
6.01
2.60
7.89
5.79
2.78
7.18
5.53
2.99
TC - Total Cooling Capacity (kW)
Indoor 27
“C/19“C
SHC - Sensible Heat Capacity (kW)
Outdoor 35
“C/24“C
IP - Input Power (kW)
Page of 111
Display