CS-E24JKES, CU-E24JKE, CS-E28JKES, CU-E28JKE - Panasonic Air Conditioner Service Manual (repair manual). Page 5

Read Panasonic CS-E24JKES / CU-E24JKE / CS-E28JKES / CU-E28JKE Service Manual online

5
2 Specifications
 MODEL
INDOOR
CS-E24JKES
CS-E28JKES
OUTDOOR
CU-E24JKE
CU-E28JKE
Performance Test Condition
EUROVENT
EUROVENT
Power Supply
Phase, Hz
Single, 50
Single, 50
V
230
230
Min.
Mid.
Max.
Min.
Mid.
Max.
C
o
o
l
i
n
g
Capacity
kW
0.90
6.80
8.10
0.90
7.65
8.60
BTU/h
3070
23200
27600
3070
26100
29300
Kcal/h
770
5850
6970
770
6580
7400
Running Current
A
9.7
11.5
Input Power
W
350
2.12k
2.70k
350
2.54k
2.95k
Annual Consumption
kWh
1060
1270
EER
W/W
2.57
3.21
3.00
2.57
3.01
2.92
Kcal/hW
2.20
2.76
2.58
2.20
2.59
2.51
Power Factor
%
95
96
Indoor Noise (H / L / QLo)
dB-A
47 / 38 / 35
49 / 38 / 35
Power Level dB
63 / 54 / 51
65 / 54 / 51
Outdoor Noise (H / L)
dB-A
52 / -
53 / -
Power Level dB
66 / -
67 / -
H
e
a
t
i
n
g
Capacity
kW
0.90
8.60
9.90
0.90
9.60
11.00
BTU/h
3070
29300
33800
3070
32700
37500
Kcal/h
770
7400
8510
770
8260
9460
Running Current
A
12.1
15.0
Input Power
W
360
2.66k
3.20k
360
3.30k
3.75k
COP
W/W
2.50
3.23
3.09
2.50
2.91
2.93
Kcal/hW
2.14
2.78
2.66
2.14
2.50
2.53
Power Factor
%
96
96
Indoor Noise (H / L / QLo)
dB-A
47 / 38 / 35
48 / 38 / 35
Power Level dB
63 / 54 / 51
64 / 54 / 51
Outdoor Noise (H / L)
dB-A
52 / -
53 / -
Power Level dB
66 / -
67 / -
Low Temp.: Capacity (kW) / I.Power (W) / COP
7.17 / 2.83k / 2.53
7.97 / 3.32k / 2.40
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP
6.13 / 2.86k / 2.14
6.77 / 3.47k / 1.95
Max Current (A) / Max Input Power (W)
14.6 / 3.20k
15.6 / 3.75k
Starting Current (A)
12.1
15.0
Compressor
Type
Hermetic Motor
Hermetic Motor
Motor Type
Brushless (4-poles)
Brushless (4-poles)
Output Power
W
1.7k
1.7k
Page of 108
Display

Click on the first or last page to see other CS-E24JKES / CU-E24JKE / CS-E28JKES / CU-E28JKE service manuals if exist.