Read Panasonic CS-E24JKES / CU-E24JKE / CS-E28JKES / CU-E28JKE Service Manual online
102
17.2. Sensible Capacity Chart
CS-E24JKES CU-E24JKE
CS-E28JKES CU-E28JKE
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.75
5.11
1.94
6.30
4.90
2.09
5.86
4.71
2.23
5.33
4.48
2.41
19.0
qC
6.80
2.12
19.5
qC
7.41
5.35
1.98
6.92
5.14
2.13
6.44
4.95
2.28
5.85
4.71
2.45
22.0
qC
8.07
5.55
2.01
7.54
5.34
2.17
7.02
5.15
2.32
6.38
4.91
2.50
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
7.59
5.75
2.33
7.09
5.52
2.50
6.59
5.30
2.68
6.00
5.04
2.89
19.0
qC
7.65
2.54
19.5
qC
8.33
6.02
2.37
7.79
5.79
2.55
7.24
5.57
2.73
6.59
5.30
2.94
22.0
qC
9.08
6.25
2.41
8.48
6.01
2.60
7.89
5.79
2.78
7.18
5.53
2.99
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)
Click on the first or last page to see other CS-E24JKES / CU-E24JKE / CS-E28JKES / CU-E28JKE service manuals if exist.