CS-E24JKES, CU-E24JKE, CS-E28JKES, CU-E28JKE - Panasonic Air Conditioner Service Manual (repair manual). Page 102

Read Panasonic CS-E24JKES / CU-E24JKE / CS-E28JKES / CU-E28JKE Service Manual online

102
17.2. Sensible Capacity Chart
CS-E24JKES  CU-E24JKE
CS-E28JKES  CU-E28JKE
Outdoor Temp. (
qC)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.75
5.11
1.94
6.30
4.90
2.09
5.86
4.71
2.23
5.33
4.48
2.41
19.0
qC
6.80
2.12
19.5
qC
7.41
5.35
1.98
6.92
5.14
2.13
6.44
4.95
2.28
5.85
4.71
2.45
22.0
qC
8.07
5.55
2.01
7.54
5.34
2.17
7.02
5.15
2.32
6.38
4.91
2.50
Outdoor Temp. (
qC)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
7.59
5.75
2.33
7.09
5.52
2.50
6.59
5.30
2.68
6.00
5.04
2.89
19.0
qC
7.65
2.54
19.5
qC
8.33
6.02
2.37
7.79
5.79
2.55
7.24
5.57
2.73
6.59
5.30
2.94
22.0
qC
9.08
6.25
2.41
8.48
6.01
2.60
7.89
5.79
2.78
7.18
5.53
2.99
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)
Page of 108
Display