CS-E24JKDS, CU-E24JKD, CS-E28JKDS, CU-E28JKD, CS-XE24JKDS, CU-XE24JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD Service Manual online

8
 MODEL
INDOOR
CS-E28JKDS
OUTDOOR
CU-E28JKD
Performance Test Condition
JIS
Power Supply
Phase, Hz
Single, 50
V
220
230
Min.
Mid.
Max.
Min.
Mid.
Max.
C
o
o
l
i
n
g
Capacity
kW
0.90
7.65
8.60
0.90
7.65
8.60
BTU/h
3070
26100
29300
3070
26100
29300
Kcal/h
770
6580
7400
770
6580
7400
Running Current
A
11.8
11.5
Input Power
W
350
2.54k
2.95k
350
2.54k
2.95k
Annual Consumption
kWh
1270
1270
EER
W/W
2.57
3.01
2.92
2.57
3.01
2.92
Kcal/hW
2.20
2.59
2.51
2.20
2.59
2.51
Power Factor
%
98
96
Indoor Noise (H / L / QLo)
dB-A
49 / 38 / 35
49 / 38 / 35
Power Level dB
65 / 54 / 51
65 / 54 / 51
Outdoor Noise (H / L)
dB-A
53 / -
53 / -
Power Level dB
67 / -
67 / -
H
e
a
t
i
n
g
Capacity
kW
0.90
9.60
11.00
0.90
9.60
11.00
BTU/h
3070
32700
37500
3070
32700
37500
Kcal/h
770
8260
9460
770
8260
9460
Running Current
A
15.3
15.0
Input Power
W
360
3.30k
3.75k
360
3.30k
3.75k
COP
W/W
2.50
2.91
2.93
2.50
2.91
2.93
Kcal/hW
2.14
2.50
2.53
2.14
2.50
2.53
Power Factor
%
98
96
Indoor Noise (H / L / QLo)
dB-A
48 / 38 / 35
48 / 38 / 35
Power Level dB
64 / 54 / 51
64 / 54 / 51
Outdoor Noise (H / L)
dB-A
53 / -
53 / -
Power Level dB
67 / -
67 / -
Low Temp.: Capacity (kW) / I.Power (W) / COP
7.97 / 3.32k / 2.40
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP
6.77 / 3.47k / 1.95
Max Current (A) / Max Input Power (W)
15.6 / 3.75k
Starting Current (A)
15.3
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Output Power
W
1.7k
Page of 112
Display