CS-E24JKDS, CU-E24JKD, CS-E28JKDS, CU-E28JKD, CS-XE24JKDS, CU-XE24JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 106

Read Panasonic CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD Service Manual online

106
17.2. Sensible Capacity Chart
CS-E24JKDS  CS-XE24JKDS  CU-E24JKD
CS-E28JKDS  CU-E28JKD
Outdoor Temp. (
qC)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.75
5.11
1.94
6.30
4.90
2.09
5.86
4.71
2.23
5.33
4.48
2.41
19.0
qC
6.80
2.12
19.5
qC
7.41
5.35
1.98
6.92
5.14
2.13
6.44
4.95
2.28
5.85
4.71
2.45
22.0
qC
8.07
5.55
2.01
7.54
5.34
2.17
7.02
5.15
2.32
6.38
4.91
2.50
Outdoor Temp. (
qC)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
7.59
5.75
2.33
7.09
5.52
2.50
6.59
5.30
2.68
6.00
5.04
2.89
19.0
qC
7.65
2.54
19.5
qC
8.33
6.02
2.37
7.79
5.79
2.55
7.24
5.57
2.73
6.59
5.30
2.94
22.0
qC
9.08
6.25
2.41
8.48
6.01
2.60
7.89
5.79
2.78
7.18
5.53
2.99
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)
Page of 112