CS-E21HKES, CU-E21HKE, CS-E24HKES, CU-E24HKE, CS-E28HKE, CU-E28HKE - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-E21HKES / CU-E21HKE / CS-E24HKES / CU-E24HKE / CS-E28HKE / CU-E28HKE Service Manual online

10
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASHT-18
PP
Motor Type
Transistor (8-pole)
Induction (6-pole)
Input Power
W
85.1
167.8
Output Power
W
30
76
Fan Speed
Q-Lo (Cool/Heat)
rpm
 1080 / 1170
Lo (Cool/Heat)
rpm
 1180 / 1280
Me (Cool/Heat)
rpm
1410 / 1500
Hi (Cool/Heat)
rpm
1640 / 1720
700 / 700
SHi (Cool/Heat)
rpm
1700 / 1720
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 30 x 19
Size (W x H x L)
mm
810 x 315 x 25.4
38.1 x 762 x 873.8
903.8
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 2.54k (350 ~ 2.95k)
Heating; 3.30k (360 ~ 3.79k)
Starting Current
A
15.3
Running Current
A
Cooling; 11.8
Heating; 15.3
Maximum Current
A
15.9
Power Factor
%
Cooling; 94
Heating; 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Page of 88
Display