CS-E18JKEW, CU-E18JKE, CS-E21JKEW, CU-E21JKE, CS-XE18JKEW, CS-XE21JKEW - Panasonic Air Conditioner Service Manual (repair manual). Page 5

Read Panasonic CS-E18JKEW / CU-E18JKE / CS-E21JKEW / CU-E21JKE / CS-XE18JKEW / CS-XE21JKEW Service Manual online

5
2 Specifications
 MODEL
INDOOR
CS-E18JKEW  CS-XE18JKEW
CS-E21JKEW  CS-XE21JKEW
OUTDOOR
CU-E18JKE
CU-E21JKE
Performance Test Condition
EUROVENT
EUROVENT
Power Supply
Phase, Hz
Single, 50
Single, 50
V
230
230
Min.
Mid.
Max.
Min.
Mid.
Max.
C
o
o
l
i
n
g
Capacity
kW
0.90
5.00
6.00
0.90
6.30
7.10
BTU/h
3070
17100
20500
3070
21500
24200
Kcal/h
770
4300
5160
770
5420
6110
Running Current
A
6.7
9.8
Input Power
W
215
1.47k
2.03k
215
2.21k
2.54k
Annual Consumption
kWh
735
1105
EER
W/W
4.19
3.40
2.96
4.19
2.85
2.80
Kcal/hW
3.58
2.93
2.54
3.58
2.45
2.41
Power Factor
%
95
98
Indoor Noise (H / L / QLo)
dB-A
44 / 37 / 34
45 / 37 / 34
Power Level dB
60 / 53 / 50
61 / 53 / 50
Outdoor Noise (H / L)
dB-A
47 / -
48 / -
Power Level dB
61 / -
62 / -
H
e
a
t
i
n
g
Capacity
kW
0.90
5.80
8.00
0.90
7.20
8.50
BTU/h
3070
19800
27300
3070
24600
29000
Kcal/h
770
4990
6880
770
6190
7310
Running Current
A
7.0
9.3
Input Power
W
245
1.54k
2.60k
245
2.10k
2.75k
COP
W/W
3.67
3.77
3.08
3.67
3.43
3.09
Kcal/hW
3.14
3.24
2.65
3.14
2.95
2.66
Power Factor
%
96
98
Indoor Noise (H / L / QLo)
dB-A
44 / 37 / 34
45 / 37 / 34
Power Level dB
60 / 53 / 50
61 / 53 / 50
Outdoor Noise (H / L)
dB-A
47 / -
49 / -
Power Level dB
61 / -
63 / -
Low Temp.: Capacity (kW) / I.Power (W) / COP
5.80 / 2.35k / 2.47
6.16 / 2.43k / 2.53
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP
4.98 / 2.41k / 2.07
5.24 / 2.54k / 2.06
Max Current (A) / Max Input Power (W)
11.7 / 2.60k
12.1 / 2.75k
Starting Current (A)
7.0
9.8
Compressor
Type
Hermetic Motor
Hermetic Motor
Motor Type
Brushless (4-poles)
Brushless (4-poles)
Output Power
W
900
900
Page of 113
Display

Click on the first or last page to see other CS-E18JKEW / CU-E18JKE / CS-E21JKEW / CU-E21JKE / CS-XE18JKEW / CS-XE21JKEW service manuals if exist.