15.2. Relationship Between The Condition Of The Air Conditioner And
Pressure And Electric Current
• Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.
Cooling Mode
Heating Mode
Condition of the
air conditoner
Low Pressure
High Pressure
Electric current 
during operation
Low Pressure
High Pressure
Electric current 
during operation
Insufficient refrigerant
(gas leakage)
Clogged capillary tube or 
Strainer
Short circuit in the indoor 
unit
Heat radiation deficiency of
the outdoor unit
Inefficient compression