Read Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Service Manual online
Basic Rotation Speed
8.1.9. Airflow Direction
1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote control).
Vertical Airflow
Operation Mode
Airflow Direction
Vane Angle (°)
1
2
3
4
5
Heating
Auto with Heat Exchanger
17
Temperature
58
7
Manual
7
17
33
49
67
Cooling, Soft Dry and Fan, Ion
Auto
7 ~ 37
Manual
7
17
25
33
41
Mode Judgment in Auto
Auto
7
Manual
7
17
25
33
41
24