CS-E10KB4EA, CU-E10HBEA - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-E10KB4EA / CU-E10HBEA Service Manual online

8
2.2.
CU-2E15LBE
Note
• Specifications are subject to change without notice for further improvement.
Item
Unit
OUTDOOR UNIT
Indoor Unit Combination
 2.5kW + 2.5kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
4.5 (1.5 ~ 5.2)
BTU/h
15300 (5120 ~ 17700)
Electrical 
Data
Running Current
A
5.75
Power Input
kW
1.23 (0.25 ~ 1.52)
EER
W/W
3.66 (6.00 ~ 3.42)
Noise
Sound Pressure Level
dB-A (H/L)
47 / -
Sound Power Level
dB (H/L)
62 / -
Heating Operation
Capacity
kW
5.4 (1.1 ~ 7.0)
BTU/h
18400 (3750 ~ 23900)
Electrical 
Data
Running Current
A
5.20
Power Input
kW
1.17 (0.21 ~ 1.67)
COP
W/W
4.62 (5.24 ~ 4.19)
Noise
Sound Pressure Level
dB-A (H/L)
49 / -
Sound Power Level
dB (H/L)
64 / -
Maximum Current
A
12.0
Starting Current
A
5.75
Circuit Breaker Capacity
A
15
Dimension
Height
mm
540
Width
mm 780 
(+70)
Depth
mm 289
Net Weight
kg 
38
Connection Cable
3 + 1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 ~ 20
Maximum Pipe Length (Total Room)
m
30
Refrigerant Pipe Diameter
Liquid Side
mm (inch)
6.35 (1/4)
Gas Side
mm (inch)
9.52 (3/8)
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Rated Output
W
1.20k
Air Circulation
Type
Propeller Fan
Motor Type
DC Motor (8-poles)
Rated Output
W
40
Fan Speed
High (Cooling / Heating)
RPM
860 / 860
Heat Exchanger
Type
Plate fin configuration forced draft type
Tube Material
Copper
Fin Material
Aluminum (Pre Coat)
Row / Stage
2 / 20
FPI
19
Air Volume
High (Cooling / Heating)
m
3
/min
33.3 / 28.5
Refrigerant Control Device
Expansion Valve
Refrigerant Oil
RB68A / Freol Alpha68M
Refrigerant (R410A)
g
1.45k
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-10
-11
Page of 98