8
2.2.
CU-2E15LBE
Note
• Specifications are subject to change without notice for further improvement.
Item
Unit
OUTDOOR UNIT
Indoor Unit Combination
2.5kW + 2.5kW
Power Source
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
Cooling Operation
Capacity
kW
4.5 (1.5 ~ 5.2)
BTU/h
15300 (5120 ~ 17700)
Electrical
Data
Running Current
A
5.75
Power Input
kW
1.23 (0.25 ~ 1.52)
EER
W/W
3.66 (6.00 ~ 3.42)
Noise
Sound Pressure Level
dB-A (H/L)
47 / -
Sound Power Level
dB (H/L)
62 / -
Heating Operation
Capacity
kW
5.4 (1.1 ~ 7.0)
BTU/h
18400 (3750 ~ 23900)
Electrical
Data
Running Current
A
5.20
Power Input
kW
1.17 (0.21 ~ 1.67)
COP
W/W
4.62 (5.24 ~ 4.19)
Noise
Sound Pressure Level
dB-A (H/L)
49 / -
Sound Power Level
dB (H/L)
64 / -
Maximum Current
A
12.0
Starting Current
A
5.75
Circuit Breaker Capacity
A
15
Dimension
Height
mm
540
Width
mm 780
(+70)
Depth
mm 289
Net Weight
kg
38
Connection Cable
3 + 1 (Earth) ø1.5 mm
2
Pipe Length Range (1 room)
m
3 ~ 20
Maximum Pipe Length (Total Room)
m
30
Refrigerant Pipe Diameter
Liquid Side
mm (inch)
6.35 (1/4)
Gas Side
mm (inch)
9.52 (3/8)
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Rated Output
W
1.20k
Air Circulation
Type
Propeller Fan
Motor Type
DC Motor (8-poles)
Rated Output
W
40
Fan Speed
High (Cooling / Heating)
RPM
860 / 860
Heat Exchanger
Type
Plate fin configuration forced draft type
Tube Material
Copper
Fin Material
Aluminum (Pre Coat)
Row / Stage
2 / 20
FPI
19
Air Volume
High (Cooling / Heating)
m
3
/min
33.3 / 28.5
Refrigerant Control Device
Expansion Valve
Refrigerant Oil
RB68A / Freol Alpha68M
Refrigerant (R410A)
g
1.45k
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
—
Minimum
16
—
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-10
-11