98
17.2. Sensible Capacity Chart
CS-E10JD3EA  CU-E10HBEA
CS-E15JD3EA  CU-E15HBEA
CS-E18JD3EA  CU-E18HBEA
Outdoor Temp. (
°C)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
°C
2.48
1.88
0.62
2.32
1.80
0.67
2.16
1.73
0.72
1.96
1.65
0.77
19.0
°C
2.50
0.68
19.5
°C
2.72
1.97
0.63
2.55
1.89
0.68
2.37
1.82
0.73
2.15
1.73
0.79
22.0
°C
2.97
2.04
0.65
2.77
1.96
0.69
2.58
1.89
0.74
2.35
1.81
0.80
Outdoor Temp. (
°C)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
°C
4.07
3.08
1.14
3.80
2.96
1.22
3.53
2.84
1.31
3.21
2.70
1.41
19.0
°C
4.10
1.24
19.5
°C
4.46
3.23
1.16
4.17
3.10
1.24
3.88
2.99
1.33
3.53
2.84
1.44
22.0
°C
4.87
3.35
1.18
4.55
3.22
1.27
4.23
3.11
1.36
3.85
2.96
1.46
Outdoor Temp. (
°C)      
Indoor wet 
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
°C
5.06
3.83
1.48
4.73
3.68
1.60
4.40
3.53
1.71
4.00
3.36
1.84
19.0
°C
5.10
1.62
19.5
°C
5.55
4.02
1.51
5.19
3.86
1.63
4.83
3.71
1.74
4.39
3.53
1.88
22.0
°C
6.05
4.16
1.54
5.66
4.00
1.66
5.26
3.86
1.77
4.78
3.68
1.91
TC - Total Cooling Capacity (kW)
Indoor 27
°C/19°C
SHC - Sensible Heat Capacity (kW)
Outdoor 35
°C/24°C
IP - Input Power (kW)