CS-E10JD3EA, U-E10HBEA, CS-E15JD3EA, CU-E15HBEA, CS-E18JD3EA, CU-E18HBEA - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual online

10
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
 MODEL
INDOOR
CS-E15JD3EA
OUTDOOR
CU-E15HBEA
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Louver Fin
Row
× Stage × FPI
× 8 × 20
Size (W 
× H × L)
mm
620
× 203.2 × 44
Outdoor Heat
Exchanger
Fin Material
Aluminium
Fin Type
Corrugated Fin
Row
× Stage × FPI
× 28 × 18
Size (W 
× H × L)
mm
22
× 711.2 × 855
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
-10
Heating
Maximum
24
18
Minimum
-10
Page of 105