CS-E10HB4EA, CS-E15HB4EA, CS-E18HB4EA, CS-E21HB4EAS, CU-E10HBEA, CU-E15HBEA, CU-E18HBEA, CU-E21HBEA - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-E10HB4EA / CS-E15HB4EA / CS-E18HB4EA / CS-E21HB4EAS / CU-E10HBEA / CU-E15HBEA / CU-E18HBEA / CU-E21HBEA Service Manual online

10
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Backward Fan
Propeller Fan
Material
ABS + GF 10%
PP
Motor Type
DC Brushless Motor (8-pole)
Transistor (8-pole)
Output Power
W
40
40
Fan Speed
QLo (Cool/Heat)
rpm
390 / 470
Lo (Cool/Heat)
rpm
430 / 490
Me (Cool/Heat)
rpm
510 / 565
Hi (Cool/Heat)
rpm
590 / 640
660 / 660
SHi (Cool/Heat)
rpm
640 / 690
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
× 10 × 18
× 34 × 17
Size (W x H x L)
mm
1330 
× 210 × 25.4
36.4 
× 714 × 823.2
           1270
                                   851.9
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230 - 240
Hz
50
Input Power
W
Cooling; 1.53k (255 ~ 1.93k)
Heating; 1.90k (260 ~ 2.45k)
Starting Current
A
8.5
Running Current
A
Cooling; 7.0 - 6.9
Heating; 8.5 - 8.3
Maximum Current
A
10.8
Power Factor
%
Cooling; 95 - 92
Heating; 97 - 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Page of 88
Display

Click on the first or last page to see other CS-E10HB4EA / CS-E15HB4EA / CS-E18HB4EA / CS-E21HB4EAS / CU-E10HBEA / CU-E15HBEA / CU-E18HBEA / CU-E21HBEA service manuals if exist.