CS-C7DKD, CU-C7DKD, CS-C9DKD, CU-C9DKD, CS-C12DKD, CU-C12DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 2

Read Panasonic CS-C7DKD / CU-C7DKD / CS-C9DKD / CU-C9DKD / CS-C12DKD / CU-C12DKD Service Manual online

 8.8. 
Horizontal Airflow Direction Control 
28
 8.9. 
Powerful Operation 
28
 8.10. Quiet Operation 
29
 8.11. Ionizer Operation 
30
 8.12. Timer Control 
31
 8.13. Random Auto Restart Control 
31
 8.14. Remote Control Signal Receiving Sound 
31
 9 Operating Instructions 
32
 10 Installation Instructions 
38
 10.1. Safety Precautions 
38
 10.2. Attached accessories 
40
 10.3. Select the best location 
40
 10.4. Indoor/Outdoor Unit Installation Diagram 
40
 10.5. Indoor unit 
41
 10.6. Outdoor unit 
44
 11 2-way, 3-way Valve 
49
 11.1. Evacuation of the Equipment 
50
 11.2. Air Purging of the Piping and Indoor Unit 
56
 12 Servicing Information 
62
 12.1. Distinction of Lead Free (PbF) Printed Circuit Board 
62
 12.2. Indoor Electronic Controller Removal Procedures 
62
 • 
High Efficiency
 • 
Compact Design
 • 
Wider range of horizontal discharge air.
 • 
Air Filter with function to reduce dust and smoke.
 • 
Automatic air swing and manual adjusted by Remote
Control for vertical airflow.
 • 
Long installation piping.
 − 
CS/CU-C7DK, CS/CU-C9DK, long piping up to 10
meter.
 − 
CS/CU-C12DK, long piping up to 15 meter.
 • 
Supersonic Air Purifying Device with SUPER alleru-
buster.
 − 
Inactive various harmful airborne elements including
allergen, viruses and bacteria.
 − 
Generated supersonic waves enhance the ability to
collect dust and dirt in the air.
 12.3. Indoor Fan Motor and Cross Flow Fan Removal
Procedures 
63
 12.4. Auto OFF/ON Button 
64
 12.5. Remote Control Reset 
65
 13 Troubleshooting Guide 
66
 13.1. Refrigeration cycle system 
66
 13.2. Relationship between the condition of the air conditioner
and pressure and electric current 
67
 13.3. Diagnosis methods of a malfunction of a compressor  67
 14 Technical Data 
68
 14.1. Thermostat characteristics 
68
 14.2. Sensible Capacity Chart 
68
 14.3. Operation characteristics 
69
 15 Exploded View (Indoor Unit) 
71
 16 Replacement Parts List (Indoor Unit) 
72
 17 Exploded View (Outdoor Unit) 
73
 18 Replacement Parts List (Outdoor Unit) 
75
 19 Electronic Circuit Diagram 
76
 19.1. Indoor Unit 
76
 19.2. Remote Control 
82
 19.3. Print Pattern Indoor Unit Printed Circuit Board 
83
 • 
Quality Improvement
 − 
Random auto restart after power failure for safety restart
operation.
 − 
Gas leakage protection.
 − 
Prevent Compressor reverse cycle.
 − 
Inner protector to protect Compressor.
 − 
Noise prevention during soft dry operation.
 − 
Blue Coated Condenser for high resistance to corrosion.
 • 
Operation Improvement
 − 
Quiet mode to provide quiet operation.
 − 
Powerful mode to reach the desired room temperature
quickly.
 − 
Ionizer control for generating negative ion in discharge
air.
 − 
24-hour timer setting.
 • 
Serviceability Improvement
 − 
Removable and washable Front Panel.
1 Features
2
CS-C7DKD CU-C7DKD / CS-C9DKD CU-C9DKD / CS-C12DKD CU-C12DKD
Page of 85
Display

Click on the first or last page to see other CS-C7DKD / CU-C7DKD / CS-C9DKD / CU-C9DKD / CS-C12DKD / CU-C12DKD service manuals if exist.