CS-C18JKD, CU-C18JKD, CS-C24JKD, CU-C24JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-C18JKD / CU-C18JKD / CS-C24JKD / CU-C24JKD Service Manual online

6
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Specifications are subjected to change without prior notice for further improvement.
Weight
Net (I/D / O/D)
kg (lb)
12 (26)
37 (82)
12 (26)
56 (123)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
6.35 (1/4) / 15.88 (5/8)
Standard Length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length Range (min - max)
m (ft)
3 (9.8) ~ 25 (82.0)
3 (9.8) ~ 25 (82.0)
I/D & O/D Height Different
m (ft)
20 (65.6)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
30 (0.3)
Length for Additional Gas
m (ft)
7.5 (24.6)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
12
12
Length
mm
550
550
Indoor Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 15 x 21
2 x 15 x 21
Size (W x H x L)
mm
810 x 315 x 25.4
810 x 315 x 25.4
Outdoor Heat Exchanger
Fin Material
Aluminium (Blue Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 24 x 17
2 x 34 x 17
Size (W x H x L)
mm
25.4 x 504 x 693.4
713.4
25.4 x 714 x 831.2
811.2
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
16
20
Thermostat
Mechanical
Protection Device
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor Operation Range
Maximum
32
23
32
23
Minimum
16
11
16
11
Outdoor Operation Range
Maximum
43
26
43
26
Minimum
16
11
16
11
MODEL
INDOOR
CS-C18JKD
CS-C24JKD
OUTDOOR
CU-C18JKD
CU-C24JKD