CS-C18JKD, CU-C18JKD, CS-C24JKD, CU-C24JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 19

Read Panasonic CS-C18JKD / CU-C18JKD / CS-C24JKD / CU-C24JKD Service Manual online

19
11 Installation Instruction
11.1. Select the Best Location
11.1.1.
Indoor Unit
• Do not install the unit in excessive oil fume area such as
kitchen, workshop and etc.
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
11.1.2.
Outdoor Unit
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over the [piping length for additional gas],
additional refrigerant should be added as shown in the table.
Example: For C18JKD
If the unit is installed at 10 m distance, the quantity of additional 
refrigerant should be 50 g .... (10-7.5) m x 20 g/m = 50 g
11.1.3.
Indoor/Outdoor Unit Installation
Diagram
Model
Horse 
Power 
(HP)
Piping size
Std. 
Length
(m)
Max. 
Ele-
vation 
(m)
Min.
Piping 
Length
(m)
Max.
Piping 
Length
(m)
Addi-
tional 
Refri-
ge-
rant 
(g/m)
Piping 
Length 
for
add. 
gas 
(m)
Gas Liquid
C7JKD
3/4 ~ 
1.5HP
3/8”
1/4”
7.5
5
3
10
10
7.5
C9JKD
5
3
10
10
7.5
C12JKD
1/2”
5
3
15
10
7.5
C18JKD 2.0 ~ 
2.5HP
5
20
3
25
20
7.5
C24JKD
5/8”
20
3
25
30
7.5
Page of 59