2.3. Outdoor Unit
• To protect compressor from reverse
rotation when there is an instantaneous
power failure.
power failure.
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
However, it stops immediately with
remote control stop signal.
Overload Protector
• Inner protector.
Compressor Reverse Rotation
Protection Control
Protection Control
Outdoor Fan Operation Control
C24DK
• 6-pole induction motor (2 speed).
• For Cooling or Soft Dry operation
• 6-pole induction motor (2 speed).
• For Cooling or Soft Dry operation
Hi-speed ............. When outdoor
temperature reaches to 31
temperature reaches to 31
°C.
Lo-speed ............. When outdoor
temperature reaches to 29
temperature reaches to 29
°C.
C18DK
• 6-pole induction motor (1 speed).
• 6-pole induction motor (1 speed).
5
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD