CS-C18DKD, CU-C18DKD, CS-C24DKD, CU-C24DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 5

Read Panasonic CS-C18DKD / CU-C18DKD / CS-C24DKD / CU-C24DKD Service Manual online

2.3. Outdoor Unit
• To protect compressor from reverse
rotation when there is an instantaneous
power failure.
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Overload Protector
• Inner protector.
Compressor Reverse Rotation
Protection Control
Outdoor Fan Operation Control
C24DK
• 6-pole induction motor (2 speed).
• For Cooling or Soft Dry operation
Hi-speed ............. When outdoor
temperature reaches to 31
°C.
Lo-speed ............. When outdoor
temperature reaches to 29
°C.
C18DK
• 6-pole induction motor (1 speed).
5
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
Page of 72