Read Panasonic CS-C18CKE / CU-C18CKE / CS-C24CKE / CU-C24CKE Service Manual online
Outdoor Unit
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
power failure.
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
However, it stops immediately with
remote control stop signal.
Overload Protector
• Inner protector.
Compressor Reverse Rotation
Protection Control
Protection Control
Outdoor Fan Operation Control
C24CK
• 6-pole induction motor (2 speed).
• For Cooling or Soft Dry operation
• 6-pole induction motor (2 speed).
• For Cooling or Soft Dry operation
Hi-speed ............. When outdoor
temperature reaches to 31°C.
Lo-speed ............. When outdoor
temperature reaches to 29°C.
temperature reaches to 31°C.
Lo-speed ............. When outdoor
temperature reaches to 29°C.
C18CK
• 6-pole induction motor (1 speed).
• 6-pole induction motor (1 speed).
5
CS-C18CKE CU-C18CKE / CS-C24CKE CU-C24CKE
Click on the first or last page to see other CS-C18CKE / CU-C18CKE / CS-C24CKE / CU-C24CKE service manuals if exist.