CS-A9CKPG, CU-A9CKP6G, CS-A12CKPG, CU-A12CKP6G - Panasonic Air Conditioner Service Manual (repair manual). Page 19

Read Panasonic CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G Service Manual online

Time Delay Safety Control
Starting Current Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Compressor Protection Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
  • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
  • During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
  • The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
off, it stops for 6 minutes.
  • Once the compressor stops, it will not start for 3 minutes during Cooling operation.
  • Same as Starting Current Control for Cooling Mode operation.
  • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
  • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
  • Same as Compressor Protection Control for Cooling Mode Operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
  • Fan speed rotates at Lo- speed.
  • Deodorizing Control.
19
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Page of 77
Display