2 Specifications
Model
Indoor
CS-A7JKD
CS-A9JKD
CS-A12JKD
Outdoor
CU-A7JKD
CU-A9JKD
CU-A12JKD
Performance Test Condition
NEW JIS
NEW JIS
NEW JIS
Power Supply
Phase, Hz
Single, 50
Single, 50
Single, 50
V
220
230
220
220
220
230
Cooling
Capacity
kW
2.00
2.00
2.65
2.65
3.52
3.54
BTU/h
6820
6820
9040
9040
12000
12100
Kcal/h
1720
1720
2280
2280
3030
3040
Running Current
A
2.9
2.8
4.1
1.0
5.1
5.1
Input Power
W
610
630
860
890
1.08k
1.12k
EER
W/W
3.28
3.17
3.08
2.98
3.26
3.16
BTU/hW
11.2
10.8
10.5
10.2
11.1
10.8
Power  Factor
%
96
98
95
97
96
95
Indoor Noise
dB-A (H/L)
33 / 26
33 / 26
36 / 26
36 / 26
39 / 29
39 / 29
Power Level dB
49 / –
49 / –
52 / –
52 / –
55 / –
55 / –
Outdoor Noise
dB-A (H/L)
46 / –
47 / –
48 / –
49 / –
48 / –
49 / –
Power Level dB
61 / –
62 / –
63 / –
64 / –
63 / –
64 / –
He
ating
Capacity
kW
2.10
2.10
2.80
2.85
4.00
4.05
BTU/h
7160
7160
9550
9720
13640
13810
Kcal/h
1810
1810
2410
2450
3440
3480
Running Current
A
2.4
2.4
3.3
3.3
5.2
5.1
Input Power
W
500
525
700
740
1.09k
1.12k
COP
W/W
4.20
4.00
4.00
3.85
3.67
3.62
BTU/hW
14.3
13.6
13.6
13.1
12.5
12.3
Power  Factor
%
95
95
96
97
95
95
Indoor Noise
dB-A (H/L)
36 / 28
36 / 28
38 / 28
38 / 28
40 / 29
40 / 29
Power Level dB
52 / –
52 / –
54 / –
54 / –
56 / –
56 / –
Outdoor Noise
dB-A (H/L)
48 / –
49 / –
48 / –
49 / –
48 / –
49 / –
Power Level dB
64 / –
65 / –
64 / –
65 / –
64 / –
65 / –
Max Current (A) / Max Input Power (W)
3.4 / 750
5.1 / 1.13k
6.0 / 1.35k
Starting Current (A)
12.4
18
20
Compressor
Type
Hermetic Motor
Hermetic Motor
Hermetic Motor
Motor Type
Induction (2-poles)
Induction (2-poles)
Induction (2-poles)
Output Power
W
550
750
950
Indoor
 Fan
Type
Cross-flow Fan
Cross-flow Fan
Cross-flow Fan
Material
ASG20K1
ASG20K1
ASG20K1
Motor Type
Induction (4-poles)
Induction (4-poles)
Induction (4-poles)
Input Power
W
46.6 - 49.5
46.6 - 49.5
46.6 - 49.5
Output Power
W
24
24
24
Speed
QLo
rpm
Cooling: 630 - 630
Heating: 630 - 630
Cooling: 660 - 660
Heating: 660 - 660
Cooling: 730 - 730
Heating: 730 - 730
Lo
rpm
Cooling: 700 - 700
Heating: 750 - 750
Cooling: 730 - 730
Heating: 780 - 780
Cooling: 800 - 800
Heating: 840 - 840
Me
rpm
Cooling: 800 - 800
Heating: 800 - 800
Cooling: 870 - 870
Heating: 870 - 870
Cooling: 950 - 950
Heating: 950 - 950
Hi
rpm
Cooling: 910 - 910
Heating: 910 - 910
Cooling: 1000 - 1000
Heating: 1000 - 1000
Cooling: 1100 - 1100
Heating: 1100 - 1100
SHi
rpm
Cooling: 980 - 980
Heating: 980 - 980
Cooling: 1040 - 1040
Heating: 1040 - 1040
Cooling: 1120 - 1120
Heating: 1120 - 1120
Out
door
 Fan
Type
Propeller Fan
Propeller Fan
Propeller Fan
Material
PP Resin
PP Resin
PP Resin
Motor Type
Induction (6-poles)
Induction (6-poles)
Induction (6-poles)
Input Power
W
66.0 - 74.8
66.0 - 74.8
71.5 - 80.3
Output Power
W
30
30
30
Speed
Hi
rpm
800 - 830
800 - 830
835 - 845
Moisture Removal
L/h (Pt/h)
1.3 (2.7)
1.6 (3.4)
2.0 (4.2)
Page of 74