8 Wiring Connection Diagram
8.1.
CS-A7JKD  CU-A7JKD
CS-A9JKD  CU-A9JKD
Resistance of Indoor Fan Motor Windings
Note: Resistance at 20
°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CS-A7JKD
CS-A9JKD
CONNECTION
CWA921413
BLUE-YELLOW
316.2 
Ω
YELLOW-RED
320.8 
Ω
MODEL
CU-A7JKD
CU-A9JKD
CONNECTION
CWA951526
BLUE-YELLOW
309 
Ω
YELLOW-RED
210 
Ω
MODEL
CU-A7JKD
CU-A9JKD
CONNECTION
2RS122D5BG02
2PS156D3DA02
C - R
5.193 
Ω
4.228 
Ω
C - S
5.557 
Ω
3.841 
Ω