Read Panasonic CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE Service Manual online
Automatic Fan Speed Mode
Heating Operating Time Diagram
When Automatic Fan Speed is selected at Remote Control during heating operation.
•
Fan speed rotates in the range of Me
→
Lo according to the heat exchanger temperature.
•
If use Manual Fan Speed,
at above diagram will operate with setting Fan Speed.
24
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE