CS-A75KE, CS-A95KE, CS-A125KE, CU-A75KE, CU-A95KE, CU-A125KE - Panasonic Air Conditioner Service Manual (repair manual). Page 18

Read Panasonic CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE Service Manual online

Compressor Protection Control
Automatic Fan Speed Mode
  • 
After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and restart
automatically. (Time Delay Safety Control is valid).
  • 
If the above phenomenon is repeated for 3 times, the compressor will stops.
  • 
The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.
When Automatic Fan Speed is selected at Remote Control during cooling operation.
  • 
Fan speed rotates in the range of Hi to Me.
  • 
Deodorizing Control.
18
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE
Page of 97
Display

Click on the first or last page to see other CS-A75KE / CS-A95KE / CS-A125KE / CU-A75KE / CU-A95KE / CU-A125KE service manuals if exist.