Cross Flow Fan Removal Procedure.
 1. (Refer to No. 4 of Indoor Fan Motor the removal
procedure)
Loosen the screw at the right side of the evaporator.
 2. Pull the left side of the evaporator forward slightly and
remove the cross Flow Fan.
(B) Disassembly of the parts (Outdoor Unit)
  • 
Inspection points for the Outdoor Electronic
Controller
 1. The Electronic Controller, Can be seen by removing the
cabinet Top plate and Front plate, as shown in the .
Fig. 8
Fig. 9
Fig. 10