Read Panasonic CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD Service Manual online
6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°FDry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.
Indoor Airflow
Lo
m
3
/min (ft
3
/m)
Cooling: 13.8 (486) - 13.8 (486)
Heating: 14.8 (523) - 14.8 (523)
Heating: 14.8 (523) - 14.8 (523)
Cooling: 15.4 (543) - 15.4 (543)
Heating: 16.6 (587) - 16.6 (587)
Heating: 16.6 (587) - 16.6 (587)
Me
m
3
/min (ft
3
/m)
Cooling: 15.1 (532) - 15.1 (532)
Heating: 15.3 (542) - 15.3 (542)
Heating: 15.3 (542) - 15.3 (542)
Cooling: 17.0 (600) - 17.0 (600)
Heating: 17.2 (606) - 17.2 (606)
Heating: 17.2 (606) - 17.2 (606)
Hi
m
3
/min (ft
3
/m)
Cooling: 16.4 (579) - 16.4 (579)
Heating: 17.1 (604) - 17.1 (604)
Heating: 17.1 (604) - 17.1 (604)
Cooling: 18.6 (657) - 18.6 (657)
Heating: 20.0 (706) - 20.0 (706)
Heating: 20.0 (706) - 20.0 (706)
SHi
m
3
/min (ft
3
/m)
16.8 (593) - 16.8 (593)
19.8 (699) - 19.8 (699)
Outdoor Airflow
Lo
m
3
/min (ft
3
/m)
28.6 (1010) - 30.5 (1080)
28.1 (990) - 29.9 (1060)
Hi
m
3
/min (ft
3
/m)
50.7 (1790) - 51.7 (1830)
49.7 (1750) - 50.7 (179)
Refrigeration Cycle
Control Device
Capillary Tube
Capillary Tube
Refrigerant Oil
cm
3
SUNISO 4GDID or ATMOS
NM56M (700)
SUNISO 4GDID or ATMOS
NM56M (1130)
Refrigerant Type
g (oz)
R22, 1710 (60.4)
R22, 2050 (72.4)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 750 (29-17/32)
290 (11-7/16) / 750 (29-17/32)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 345 (13-19/32)
235 (9-9/32) / 345 (13-19/32)
Weight
Net (I/D / O/D)
kg (lb)
12 (26) / 60 (132)
12 (26) / 60 (132)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4”) / 12.7 (1/2”)
6.35 (1/4”) / 15.8 (5/8”)
Standard length
m (ft)
5 (16.4)
7.5 (24.6)
Length range (min~max)
m (ft)
3~25 (9.8~82.0)
3~25 (9.8~82.0)
I/D & O/D Height different
m (ft)
20.0 (65.6)
20.0 (65.6)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
30 (0.3)
Length for Additional Gas
m (ft)
7.5 (24.6)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
12
12
Length
mm
560
560
Indoor Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row
u Stage u FPI
2
u 15 u 21
2
u 15 u 21
Size (W
u H u L)
mm
810
u 315 u 25.4
810
u 315 u 25.4
Outdoor Heat Exchanger
Fin Material
Aluminium (Blue Coat)
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Corrugated Fin
Row
u Stage u FPI
2
u 28 u 17
2
u 23 u 17
Size (W
u H u L)
mm
44
u 711.2 u 782.4
816.9
44
u 711.2 u 782.4
816.9
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Indoor Power Supply
Indoor Power Supply
Power Supply Cord
A
16
20
Thermostat
—
—
Protection Device
Inner Protector
—
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
32
23
Minimum
16
11
16
11
Heating
Maximum
30
—
30
—
Minimum
16
—
16
—
Outdoor Operation Range
Cooling
Maximum
43
26
43
26
Minimum
16
11
16
11
Heating
Maximum
24
18
24
18
Minimum
-5
-6
-5
-6
Click on the first or last page to see other CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD service manuals if exist.