CS-A18JKD, CU-A18JKD, CS-A24JKD, CU-A24JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 13

Read Panasonic CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD Service Manual online

13
8 Wiring Connection Diagram
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 20
qC of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
qC of ambient temperature.
MODEL
CU-A18JKD
CU-A24JKD
CONNECTION
CWA951385J
CWA951353J
BLUE - YELLOW
93 
:
74.6 
:
YELLOW - ORANGE
124 
:
122.2 
:
YELLOW - RED
98 
:
83.4 
:
MODEL
CU-A18JKD
CU-A24JKD
CONNECTION
2JS318D3AA04
2JS438D3JA02
C - R
1.618 
:
0.830 
:
C - S
3.718 
:
2.257 
: