Read Panasonic CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD Service Manual online
13
8 Wiring Connection Diagram
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 20
qC of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
qC of ambient temperature.
MODEL
CU-A18JKD
CU-A24JKD
CONNECTION
CWA951385J
CWA951353J
BLUE - YELLOW
93
:
74.6
:
YELLOW - ORANGE
124
:
122.2
:
YELLOW - RED
98
:
83.4
:
MODEL
CU-A18JKD
CU-A24JKD
CONNECTION
2JS318D3AA04
2JS438D3JA02
C - R
1.618
:
0.830
:
C - S
3.718
:
2.257
:
Click on the first or last page to see other CS-A18JKD / CU-A18JKD / CS-A24JKD / CU-A24JKD service manuals if exist.