7
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C D.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coated)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage X FPI
2 x 15 x 21
2 x 28 x 17
Size (W x H x L)
mm
810 x 315 x 25.4
25.4 x 711.2 x 791
             826
Air Filter
Material
Polypropelene
Type
One-Touch
ITEM
UNIT
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
kW
Cooling: 2.54 - 2.58
Heating: 2.53 - 2.56
Starting Current
A
65
Running Current
A
Cooling: 12.3 - 12.2
Heating: 12.2 - 12.2
Maximum current
A
15.8
Power Factor
%
Cooling: 94 - 92
Heating: 94 - 91
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Number of Core
3 (2.5mm
2
)
Power Cord
Length
m
1.9
Thermostat
Protection Device
Inner Protector
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT