5
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C D.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
ITEM
UNIT
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
kW
Cooling: 1.72 - 1.76
Heating: 1.65 - 1.71
Starting Current
A
44.5
Running Current
A
Cooling: 8.0 - 7.8
Heating: 7.7 - 7.6
Power Factor
%
Cooling: 98 - 98
Heating: 97 - 98
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
10.2
Number of Core
3 (1.5mm
2
)
Power Cord
Length
m
1.9
Thermostat
Protection Device
Inner Protector