CS-A18DKD, CU-A18DKD, CS-A24DKD, CU-A24DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 4

Read Panasonic CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD Service Manual online

2.2. Indoor Unit
Ionizer Operation
• Generate and discharge negative ion.
Random Auto Restart Control
• Unit will be restarted, when resume from
power failure, at previous setting.
Anti-Freezing Control
• To prevent indoor heat exchanger from
freezing.
Indoor Fan Speed Control
• Manual control fan speed
(High, Medium and Low).
• Automatic fan speed
Vertical airflow control can be adjusted
automatically or manually by remote control.
Horizontal airflow control can be adjusted
automatically or manually by remote control.
Airflow Direction Control
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode.Use when the remote
control cannot be used.
• Press for > 5 second to operate Cooling
operation mode and compressor force
to on (“beep” sound will be heard). Used 
when test running or servicing.
• Within 20 second of Cooling operation, 
press continuously for > 5 second to enter 
various setting mode. “beep, beep” sound 
will be heard. (Used to toggle remote 
control signal receiving sound or select 
remote control transmission code.) 
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
 (Green) ........ Lights up in operation,
blinks in Automatic
Operation judging.
QUIET
 (Orange) ........ Lights up in Quiet
Operation.
TIMER
 (Orange) ....... Lights up in Timer
Setting.
POWERFUL
 (Orange) .. Lights up in Powerful
Operation.
ION
 (Green) ........... Lights up in Ionizer
Operation.
SUPER 
ALLERU-BUSTER
 (Blue) ... Lights up in operation.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic 
Operation.
Powerful Operation
• Reaches the desired room temperature 
quickly.
Timer Operation
• Delay OFF/ON Timer control.
Time Delay Safety Control
• Restarting is inhibited for approximately
3 minutes.
Quiet Operation
• To provide quiet operation.
7 Minutes Time Save Control
• To reduce the built up humidity inside
the room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor
unit discharge area.
Hot-Start Control
• To prevent cold air being discharge during
Heating operation starts.
Anti Cold Draft Control
• To prevent the cold draft during Heating
mode operation in thermo off condition.
4
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Page of 86
Display

Click on the first or last page to see other CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD service manuals if exist.