CS-A18CKE, CU-A18CKE, CS-A24CKE, CU-A24CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 4

Read Panasonic CS-A18CKE / CU-A18CKE / CS-A24CKE / CU-A24CKE Service Manual online

Indoor Unit
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
Heating : Fan speed varies from Me
 SSLo in accordance with
indoor heat exchanger.
Cooling : Fan rotates at Hi, Me and
Lo- speed. Deodorizing
control is available.
Soft Dry : Fan rotates at Lo- speed.
Deodorizing control is
available.
• Automatic air swing and manual adjusted
by remote control for vertical and horizontal
airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be
used.)
• Press continuously for 5s or < 10s  to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
 (Green) .......... Lights up in operation,
blinks in Automatic
Operation Mode judging
and Hot Start operation.
QUIET
 (Orange) ......... Lights up in Quiet Mode
Operation.
TIMER
 (Orange) ......... Lights up in Timer Setting.
POWERFUL
 (Orange) ... Lights up in Powerful
Mode Operation.
 (Green) ............ Lights up in Ionizer
Mode Operation.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Mode.
Powerful Operation
• Reaches the desired room temperature quickly.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
Quiet Operation
• To provide quiet operation.
7 Minutes Time Save Control
• Cooling Operation only.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Hot-Start Control
• At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30
°C.
Anti Cold Draft Control
• The indoor fan operates at Lo
 (30 sec.)
after that SSLo when the indoor heat
exchanger temperature is low.
(During Heating mode thermal off)
4
CS-A18CKE CU-A18CKE / CS-A24CKE CU-A24CKE
Page of 89
Display

Click on the first or last page to see other CS-A18CKE / CU-A18CKE / CS-A24CKE / CU-A24CKE service manuals if exist.