CS-A18BD3P, CU-A18BBP5 - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-A18BD3P / CU-A18BBP5 Service Manual online

ELECTRICAL DATA (50Hz)
4 SPECIFICATION (COOLING ONLY TYPE )
4.1 CS-A18BD3P / CU-C18BBP5
ITEM / MODEL
Indoor Unit
Outdoor unit
Main Body
CS-A18BD3P
CU-C18BBP5
Cooling Capacity
kW
5.00
(BTU/h)
(17,100)
Refrigerant Charge-less
m
10
Standard Air Volume for High
m
3
/min
Hi 17
-
Medium and Low Speed
cfm
Hi 600
-
External Static Pressure
mmAq
7
-
Pa
69
Air Inlet
Backward Suction
Rear sided Suction
Air Outlet
Front blow-out
Front blow-out
Outside Dimension (H x W x D)
mm
270 x (780 + 100) x 650
685 x 800 x 300
Net Weight
kg (lbs)
34 (75)
52 (115)
Piping Connection Refrigerant
Gas
mm (inch)
O.D Ø 12.7 (1/2) Flared Type
Liquid
mm (inch)
O.D Ø 6.35 (1/4) Flared Type
Drain
mm
Female screw RC1 (PT1)
I.DØ 20 x 1
Compressor
Type, Number of Set
-
Hermetic-1 (Rotary), 1
Starting
Method
-
Direct on-line starting
Motor
Type
-
2-pole single phase induction
motor
Input
kW
-
Cool/2.31
Rated Output
kW
-
1.5
Fan
Type, Number of Set
Sirocco fan-2
Prop. fan-1
Air Volume Control
Three-Step and Auto mode
-
(Remote Control)
Motor
Type
4-pole single phase induction motor
6-pole single phase induction
motor
Input
kW
0.15
0.11
Rated Output
kW
0.085
0.045
Air-heat exchanger
Louvre-fin type
Louvre-fin type
Refrigerant Control
Capillary tube
Capillary tube
Refrigerant oil (Charged)
L
-
M60 (0.67)
Refrigerant (Charged)
kg (oz)
-
R-22 1.6 (56)
Running
Adjustment
Control Switch
Wired Remote Control
-
Room Temperature
Thermostat (Main Body)
-
Safety Devices
Internal protector for compressor, Internal thermostat for F.M, Crankcase
heater, High pressure switch, Current Transformer
Noise Level (Sound Pressure)
dB (A)
Hi 37 Lo 33
Hi 54
Power level dB
Hi 52 Lo 48
Hi 67
 1. Cooling capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temp. 35°C
D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
MODEL / ITEM
CS-A18BD3P/CU-C18BBP5
Condition by JIS B 8616
Volts
V
220
230
240
Phase
Single
Single
Single
Input Power
kW
Cool
1.95
1.95
1.95
Running Current
A
Cool
9.0
8.9
8.8
Starting Current
A
38
40
42
Power Factor
%
Cool
98
95
92
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Power source
AC, 1~220V, 230V, 240V 50Hz
8
Page of 102
Display

Click on the first or last page to see other CS-A18BD3P / CU-A18BBP5 service manuals if exist.