Indoor Unit
Sleep Mode Auto Control
• Indoor Fan operates refer to Indoor Fan
Speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
Heating : Fan speed varies from Me 
SSLo in accordance with
indoor heat exchanger.
Cooling : Fan rotates at Hi, Me and
SLo speed.
Soft Dry : Fan rotates at Lo- speed.
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s  to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
 
(Green) ......... Lights up in operation,
blinks in Automatic
Operation Mode judging,
deice operation and
hotstart.
SLEEP
 
(Orange) ......... Lights up in Sleep Mode
Operation.
TIMER
 (Orange) ....... Lights up in Timer
Setting.
AIR SWING
 
(Orange) ... Lights up in Auto Air
Swing Mode Operation.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Mode.
30 Minutes Time Save Control
• Heating Operation only.
Hot-Start Control
• At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
• The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
(During Heating mode thermal off)
3
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Page of 73