WT-Y118S - LG Washing Machine Service Manual (repair manual). Page 40

Read LG WT-Y118S Service Manual online

40
ERROR DECISION
CAUSE FOR ERROR
BASIS
OCCURRENCE
REMEDY
ERROR
• LID is opened in the
course of
intermittent spin,
normal spin or
processing
reservation.
• SIGNAL
continuously ringing.
• Water Pressure
Switch is off.
• AUTO OFF relay
S/W is out of order.
DOOR
OPEN
PRESSURE
SENSOR
AUTO
OFF
MOTOR
ERROR
• Lid is opened during intermittent
spin or normal spin?
• Lid is opened while processing
reservation?
• Connector to the S.F S/W or
VIOLET(VL) 2 PIN
CONNECTOR to the P.W.B ASM
has bad connection.
• S.F S/W or BALL PRESSURE
SENSOR is bad or bad contact.
• Is placed magnetic in LID-B?
• Connector the Ball Pressure
Sensor(Pressure Switch) or
BLUE(BL) 3 pin connector to
P.W.B ASM has bad connection.
• Ball Pressure Sensor
(Pressure Switch) is bad.
(In the initial state of QC TEST
MODE, the number on the
DISPLAY is less than 63 or
more than 70)
• BLUE(BL) 1pin connector to
P.W.B ASM has bad connection.
• Connector the HALL Sensor or
Natural 6 Pin connector to P.W.B
ASM had bad connection .
• Connector the stator ASM, and
YELLOW(GREEN) 3 Pin or
Natural 6 Pin connector to P.W.B
ASM had bad connection
• Hall sensor is bad.
• Locked by Bearing Housing
• Closed the lid.
• Closed the lid.
• Correct the connector contact.
• Check and replace S.F S/W or
BALL PRESSURE SENSOR.
• Change the LID-B.
• Correct the connector contact.
• Replace Ball Pressure
Sensor(Pressure Switch).
• Correct the connector contact.
• Change P.W.B ASM.
• Correct the connect contact.
• Change Stator ASM.
• Change Bearing Housing ASM.
• Change P.W.B ASM.
• Change Stator ASM.
Page of 57