Read LG WT-R10686 Service Manual online
5-5. INLET VALVE ASSEMBLY
55
Wiring
diagram
Function
Test
points
and
Result
Circuit in the MAIN PCB
Wiring diagram
INLET VALVE
Inlet valve driving circuit
Depending on the cycle and water temperature, the controller will energize the hot or cold water
valve solenoids to meet the selected water temperature.
After unplugging the connector of the defective valve, check the resistance.
(1)
(2)
(2)
(2)
(2)
(2)
(1)
(1)
(1)
(1)
* Each circuits of loads in wiring diagram are all same.
Test
Points
(1)-(2)
Result
28.5~31.5 k Ω
Click on the first or last page to see other WT-R10686 service manuals if exist.