Read LG WM3632HW Service Manual online
16
ERROR SYMPTOM
CAUSE
OVER
CURRENT
ERROR
• MAIN PWB ASSEMBLY is out of order.
• Winding in the STATOR ASSEMBLY is short-circuited.
• The connector (3-pin, male, white) in the MOTOR
HARNESS is not connected to the connector
(3-pin, female, white) of STATOR ASSEMBLY.
(3-pin, female, white) of STATOR ASSEMBLY.
• The electric contact between the connectors
(3-pin, male, white) in the MOTOR HARNESS
and 4-pin, female, white connector in the MAIN PWB
ASSEMBLY
is bad or loose.
and 4-pin, female, white connector in the MAIN PWB
ASSEMBLY
is bad or loose.
• The MOTOR HARNESS between the STATOR
ASSEMBLY and MAIN PWB ASSEMBLY is cut (open
circuited).
circuited).
• The hall sensor is defective.
8
9
LOCKED
MOTOR
ERROR
• Loose Ball Sensor Connector.
• Ball Sensor is out of order.
• Ball Sensor is out of order.
Displayed only when the START/PAUSE button is first
pressed in the QC Test Mode.
pressed in the QC Test Mode.
10
BALL SENSOR
ERROR
• The washer experienced a power failure.
12
POWER
FAILURE
• The Dry Heater is out of order.
- Replace the Dry Heater.
• The connector of the Dry Heater is not connected
properly to the connector in the main PWB ASSEMBLY.
- Reconnect or repair the connector.
- Reconnect or repair the connector.
• The Dry Fan Motor is out of order.
- Replace the fan motor.
13
DRY
HEATER
ERROR
• EEPROM is out of order.
Displayed only when the START/PAUSE button is first
pressed in the QC Test Mode.
pressed in the QC Test Mode.
11
EEPROM
ERROR
Click on the first or last page to see other WM3632HW service manuals if exist.