7. TEST MODE
19
7-1. SAFETY CAUTION
There's built-in AC 120V and DC power in output terminal of PWB assembly in common. Be careful electric
shock when disconnecting parts while trouble shooting. (Wear Electro Static Discharge gloves when working.)
After cutting off the power when changing PWB assembly, disconnect or assemble.
Be careful static when handling PWB assembly, and use Electro Static Discharge plastic pack when delivering
or keeping it.
shock when disconnecting parts while trouble shooting. (Wear Electro Static Discharge gloves when working.)
After cutting off the power when changing PWB assembly, disconnect or assemble.
Be careful static when handling PWB assembly, and use Electro Static Discharge plastic pack when delivering
or keeping it.
7-2. LOAD TEST MODE
The washer must be empty and the controls must be in the off state.
1. Press the WASH/RINSE and SPIN SPEED buttons simultaneously.
2. Press the Power button, while the above condition. Then buzzer will sound twice.
3. Press the Start/Pause button repeatedly to cycle through the test modes.
1. Press the WASH/RINSE and SPIN SPEED buttons simultaneously.
2. Press the Power button, while the above condition. Then buzzer will sound twice.
3. Press the Start/Pause button repeatedly to cycle through the test modes.
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
Press the
DELAY WASH and WASH/RINSE buttons simultaneously.
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
Turns on all lamps and locks the door.
Tumble clockwise.
Low speed Spin.
High speed Spin.
Inlet valve for prewash turns on.
Inlet valve for main wash turns on.
Inlet valve for hot water turns on.
Inlet valve for bleach turns on.
Tumble counterclockwise.
Drain pump turns on.
Off
rpm (42~50)
rpm (55~65)
rpm (105~115)
Water level frequency (225~265)
Water level frequency (225~265)
Water level frequency (225~265)
Water level frequency (225~265)
rpm (42~50)
Water level frequency (225~265)
The digits indicate the water level frequency.
For example, if the display indicate 41,
the water level frequency is 20+(41X0.1) = 24.1 kHz.
the water level frequency is 20+(41X0.1) = 24.1 kHz.
Number of times the
Start/Pause button is pressed
Check Point
Display Status