Read LG WF-T1207TP Service Manual online
34
2) Disassembly of Back Panel, Power
Cord, Inlet Valve & BP Sensor
Remove two back panel fixing screws in the
back side.
back side.
Disassemble the back panel.
Disconnect two connectors and disassemble
the power cord.
the power cord.
Remove a valve fixing screw & disconnect the
leads form the inlet valve.
leads form the inlet valve.
Remove the inlet valve.
Disconnect the leads & the pressure tube from
the BP sensor.
the BP sensor.
Remove the BP sensor.
Hinge Pin
Hinge Pin
BP sensor
Power cord
Inlet valve
Back Panel