Read LG WF-T1202TP / WF-T1205TP Service Manual online
43
4) Water doesn’t come into the wash bowl.
5) Water fills continuously or intermittently.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Wrong Installation/Leakage
1. Check whether the drain hose is
laying down on the floor.
(For pump model)
2. Check where water leaks.
Ball Pressure Sensor
(Pressure Switch)
(Pressure Switch)
1. Check the pulsator is rotating when
water fills continuously.
2. If there is no defect in the Ball
Pressure Sensor(Pressure Switch),
check whether the air hole of the outer
tub is blocked.
check whether the air hole of the outer
tub is blocked.
Inlet Valve
1. Does water fills even though it is not
energized (power is off)?
Controller
1. Does water fill immediately after the
power switch turns on before pushing
the START/PAUSE button.
the START/PAUSE button.
Drain hose
laying down.
laying down.
Water leaks
from a part.
from a part.
It doesn’t
rotate.
rotate.
Blocked.
Water fills.
Wrong installation.
Defect of the part.
Water pressure is not
sensed.
sensed.
Air hole blocked.
Defect of the inlet
valve.
valve.
Short circuit of the
triac of the
controller.
triac of the
controller.
The drain hose should be
hung on the
stand-pipe or the tub.
hung on the
stand-pipe or the tub.
Change the part.
Repair it.
Check the tube of the
Ball Pressure
Sensor(Pressure Switch),
it is bent
or blocked, repair that.
Ball Pressure
Sensor(Pressure Switch),
it is bent
or blocked, repair that.
Repair the blocked hole.
Change the inlet valve.
Change the controller.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Ball Pressure Sensor
(Pressure Switch)
(Pressure Switch)
1. Is there PE error on the display
which means Ball Pressure Senosr
(Pressure Switch) error
(Pressure Switch) error
2. Check frequency of the Ball
Pressure Sensor(Pressure Switch)
without load if wash is proceeding
without filling.
without load if wash is proceeding
without filling.
Controller
1. Defect of controller is highly possible
if inlet valve and Ball Pressure
Sensor have no defects in the above.
Sensor have no defects in the above.
Reconnect the connector
or change leads. Change
the Ball Pressure Sensor
(Pressure Switch)
or change leads. Change
the Ball Pressure Sensor
(Pressure Switch)
if coil is open.
Change the
Ball Pressure Sensor
(Pressure Switch).
Ball Pressure Sensor
(Pressure Switch).
Change the controller.
PE Error
displayed.
displayed.
Less then
26.2
26.2
Connector is taken
off, or lead or coil is
open.
off, or lead or coil is
open.
Defect of the Ball
Pressure Sensor
(Pressure Switch)
Pressure Sensor
(Pressure Switch)
Click on the first or last page to see other WF-T1202TP / WF-T1205TP service manuals if exist.