2) Disassembly of Back Panel, Power
Cord, Inlet Valve & BP Sensor
Remove two back panel fixing screws in the
back side.
back side.
Disassemble the back panel.
Disconnect two connectors and disassemble
the power cord.
the power cord.
Remove a valve fixing screw & disconnect the
leads form the inlet valve.
leads form the inlet valve.
Remove the inlet valve.
Disconnect the leads & the pressure tube from
the BP sensor.
the BP sensor.
Remove the BP sensor.
3) Disassembly of Lid Assembly,
Top Cover, Tub Cover, Pulsator
& Inner Tub
& Inner Tub
Remove Q-spring & two hinge pins then
disassemble the lid assembly
disassemble the lid assembly
Remove two top cover fixing screws in the
rear then disassemble the top cover.
rear then disassemble the top cover.
Remove tub cover fixing screws then
disassemble the tub cover.
disassemble the tub cover.
Remove the pulsator fixing screw then
disassemble the pulsator.
disassemble the pulsator.
Remove the hub fixing nut by a special tool.
Disassemble the inner tub.
Inlet valve
Power cord
BP sensor
Q-spring
Hinge Pin
Hinge Pin