Read LG WF-N1007MW / WF-N1208MW / WF-N1408MW Service Manual online
38
1
Remove the BACK COVER.
2
Unscrew the bolt to pull out the ROTOR
assembly.
assembly.
1
Disconnect the wiring connector.
2
Unscrew 6 bolts from the STATOR.
3
Remove the STATOR.
1
Pull out the hinge, pressing its snap.
2
Do not use the pulled-out hinge again. It may
be taken off during operation.
be taken off during operation.
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY
Rotor
Bolt
(1)
Hinge,
Damper
Damper
(ROTOR ASSEMBLY)
(STATOR ASSEMBLY)
(DAMPER)
• V ~ U (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
• U ~ W (8~11Ω)
• W ~ V (8~11Ω)
Note : Hook of connector (1) is on the backside
Motor Stator
U V W
• Common ~ Ha (5~15kΩ)
• Common ~ Hb (5~15kΩ)
• Common ~ Hb (5~15kΩ)
Hall Sensor
Ha
Hb
Common
Click on the first or last page to see other WF-N1007MW / WF-N1208MW / WF-N1408MW service manuals if exist.