WF-D110M - LG Washing Machine Service Manual (repair manual). Page 54

Read LG WF-D110M Service Manual online

5 3
4-9-3. HALL SENSOR
(3)
)
4
(
)
2
(
)
1
(
- Voltage Testing Hall Sensor from the Main PCB Assembly
1. Unplug power cord.
2. Remove rear panel.
3. Remove Washer Top.
4. Remove Main PCB Assembly cover as shown in Figure below.
5. Locate the white Hall Sensor 4 wire connector using wiring diagram wire colors as your guide.
6. Plug in power cord, close door, and press power button. DO NOT  PRESS START!
7. Place meter leads on Brown & Yellow wires. You should read 10 to 15 Vdc  output from the Main
PCB Assembly to the Hall sensor. If no 10 to 15 Vdc is  measured the control board is defective.
7. To measure output signal voltage from the hall sensor, carefully  move test leads to terminals 1
to 4, blue and gray. Slowly rotate motor rotor by hand. You should read a pulsing 10 Vdc. If 10
Vdc is measured from  1 to  4,  move  lead  on  blue  wire  to  red  wire,  terminal  2.  Repeat  rotating
m ot or   r oto r   b y  h and .  You  s h o u ld    r e ad  a   pu l s i n g  10  V d c   from   r ed  to  gr a y.  
8. If pulsing 10 Vdc is measured from 1 to 4 and 2 to 4, hall sensor  is OK! If  either  test  netted
only  9  to  10  Vdc  without  changing  (no  pulsing)  the  hall    sensor  is  likely  defective.  Disconnect 
power  by  unplugging  washer  and  ohm  check  hall  sensor  to  verify  failure  of  the  hall  sensor.
8. Place meters leads on Blue to yellow. Turn motor rotor slowly by hand. You should measure a 
pulsing  10  Vdc.  Place  meter  leads  on  Red  to  Yellow.  Turn  motor  rotor  slowly  by  hand.  You
should  measure  a  pulsing  10  Vdc.  If  both  tests  measure  a  pulsing  10  Vdc,  hall  sensor  and
harness OK. If either or both tests measures 9 to 10 volts, but does not pulse or change, Hall
sensor has failed and must be replaced. IF zero (0) voltage is measured on either test, check
r e d   &   b l u e   w i r e s   f o r   c o n t i n u i t y .   R e p a i r   o r   r e p l a c e   h a r n e s s   a s   n e e d e d . 
Pulsing Signal
Pulsing Signal
Voltage Input
Remarks
Result
Test Points
Pulsing Signal
Pulsing Signal
Voltage Input
Remarks
Result
Test Points
Test 
Point
and
Result
(Hall
Sensor)
)
8
(
)
6
(
)
5
(
)
7
(
Page of 59
Display