2) Defects on displaying function
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Main voltage
1. Measure mains voltage at the wall 
outlet
2.  Meaure voltage at the extended 
outlet that the washer is plugged in 
if the extended outlet is used and 
voltage at the electrical outlet
is normal in the above.
Transfomer
1. Measure the secondary voltage of 
the transfomer.
Controller
1. Defect of LED.
2. Defect of LED driving circuit.
3. Defect of micom.
Less than 85%
of the rating.
Less than 85%
of the rating
Less than
AC 10V
Low voltage. 
The dia of the lead 
wire is smaller or 
many loads are 
connected at the 
same outlet
Defect of the
transfomer.
Defect of controller.
To explain that it is 
caused by low voltage in 
electric supply and
recommend using a 
transfomer if voltage has
been continuously low.
To use a transfomer 
having a enough
capacity if using 
a transfomer.
Change the controller.
Change the controller.
3) Reset During operation
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Mains Voltage
1. Measure voltage of the outlet that the 
washer is plugged into during wash and 
spin.
2. Reset symptom happens at specific 
time zone repeatedly.
3. Check whether a transfomerlent
power cut happens.
(Fluorescent lamp is 
transfomeriently blinked.)
Less than 
80% of the rating.
Mains voltage is too
low or size of a lead
wire is too small.
External noise 
inrushed.
Explain that it is caused 
by low voltage in electric 
mains and recommend
using a suitable size of
leads.
Explain it is caused by 
using environment.
(It happens when 
equipment with high 
frequency is used 
around)
Explain it is a problem of 
electric supply 
environment.