7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR
AT OPERATING CONDITION.
Press the
Favorite
and
Option (Left)
button simultaneously.
Press the
Option (Left)
and
Temp.
button simultaneously.
The digits means water level frequency. (10
-1
kHz)
ex) 241 : Water level frequency = 241 x 10
-1
kHz
24.1 kHz
Thermistor in tub temperature.