AC 220-240V
(1)
Replace the thermistor
Push the thermistor
tightly to the rubber.
When disconnecting the connector (1) on the
PWB assembly (Main) is the resistance of the
Natural connectors [ (White),
PWB assembly (Main) is the resistance of the
Natural connectors [ (White),
(Blue White)] between 2.5kΩ to 180kΩ
(105°C~0°C)?
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE