Read LG WD-80160NUV / WD-80160SUV / WD-80163N / WD-80163S / WD-80164NV / WD-80164S / WD-80164SV Service Manual online
23
Replace the thermistor
Push the thermistor
tightly to the rubber.
When disconnect the connector (1) on the
PWB assembly (Main) is the resistance of the
Natural connectors [ (White),
PWB assembly (Main) is the resistance of the
Natural connectors [ (White),
(Blue White)] between 2.5k
Ω
to 180k
Ω
(105°C~0°C)?
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE