Read LG WD-80130TUP Service Manual online
22
AC 220-240V
(1)
Replace the thermistor
Push the thermistor
tightly to the rubber.
When disconnecting the connector (1) on the
PWB assembly (Main) is the resistance of the
Natural connectors [ (White),
PWB assembly (Main) is the resistance of the
Natural connectors [ (White),
(Blue White)] between 2.5kΩ to 180kΩ
(105°C~0°C)?
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
Click on the first or last page to see other WD-80130TUP service manuals if exist.