41
VALVE (PRE)
VALVE (MAIN)
VALVE (DRY)
VALVE (HOT)
1 Disconnect the wiring connector.
1
2
3
4
2 Remove the valve by two screws of the valve
holder.
• Rating : 240V 50Hz
• Resistant : 3.5~4.5kΩ
• Resistant : 3.5~4.5kΩ
When reconnecting the connector
1 Open the door completely.
2 Remove the three screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
water.
Pull it out from hose.
GY/WH - BK
WH/BK - BK
YL/BK - BK
BK/WH - BK
INLET VALVE
DOOR
Removing method of remained water