40
DRY HEATER TROUBLE
After power off, is the resistance of
dry heater 10 ~ 40Ω?
Replace the dry heater.
YES
NO
Is thermostat closed?
Replace the thermostat.
YES
NO
When checking voltage between connectors
(  1  ,  2  ) on drying, is the voltage
AC 120V as the figure?
(Wire color :       - Red,      - Blue)
Replace the PWB assy
(Main)
NO
1
2