WD-1250BRD - LG Washing Machine Service Manual (repair manual). Page 17

Read LG WD-1250BRD Service Manual online

16
ERROR
SYMPTOM CAUSE
8
9
• The connector in the LEAD WIRE ASSEMBLY is not connected to
the connnector of STATOR ASSEMBLY
☞ Reconnect or repair the connector
• The hall sensor is out of order/defective.
☞ Replace the STATOR ASSEMBLY
• The Dry Heater is out of order
☞ Replace the Dry Heater
• The Connector of the Dry Heater is not connected properly to the
connector in the Main PWB ASSEMBLY
☞ Reconnect or repair the connector
• The Dry fan motor is out of order
☞ Replace the fan Motor.
MOTOR
ERROR
DRY
HEATOR
ERROR