WD-1021FB - LG Washing Machine Service Manual (repair manual). Page 34

Read LG WD-1021FB Service Manual online

33
(WASH)
(RINSE)
220-240V~
NO
NO
YES
YES
NO
AC 220-240V
PWB ASSEMBLY (MAIN)
PWB ASSEMBLY (POWER)
Replace the sensor 
(pressure).
Replace the PWB
assembly (Main).
Clean the air chamber
and hose.
Replace the sensor.
(pressure)
When pressing WASH
(    ) and RINSE ( 
)
button at the same time after draining, is  the water
level frequency 252 or more?  
When pressing  WASH
(    ), RINSE (    )
buttons at the same time while wash, is the water
level frequency between 220~240?
Checking voltage between two pins as press
the power button is the voltage 220-240V~?
Are there any problem at air chamber, the hose or
pressure sensor?
Replace the PWB assembly.
(POWER or MAIN)
HEATING WITHOUT WATER
■  WD-1223(5)F(H)(B)/WD-1243(5)F(H)(B) / WD-1041(3)F(H)B / WD-102(4)1(5)F(H)B / WD-803(4)0F(H)B
■  WD-803(4)0(W)(F)(H)/WD-102(4)1(5)W(F)(H)/WD-1042F(H)
Page of 50
Display